Jincheng Industrial Air Conditioning—Performance and Operation of Industrial Air Conditioning
Industrial air conditioners refer to air conditioners that provide environmental temperature, humidity, and cleanliness guarantees for the reliable operation of industrial product production processes or industrial process equipment. For example, constant temperature and humidity air conditioners used to ensure the normal operation of electrical control indoor equipment, high temperature environment special air conditioners used in mobile bridge cranes in steelmaking workshops, low temperature unit air conditioners used in meat processing workshops, etc. Belongs to industrial air conditioners.
The power consumption of industrial air conditioners is generally relatively large, ranging from tens of kW to several thousand kW, generally 3N ~ 380V50Hz power supply. Industrial air conditioners are generally designed to operate 24 hours a day and throughout the year, with a service life of more than 15 years. Therefore, the main components of industrial air conditioners such as compressors, condensers, throttling devices, evaporators, fans, motors, electrical components, etc., all use well-known brand products with high performance and reliability.
In terms of manufacturing process, industrial air conditioners generally use all-steel sheet metal structure and panel electrostatic spray paint treatment. Has high anti-corrosion durability. Industrial air conditioners must be tested for performance before leaving the factory to ensure that they meet the design requirements. After being transported to the user, the unit will be officially put into operation only after the successful commissioning.
Operation of industrial air conditioner controller: When the temperature is high and the room needs to be cooled down, directly press the "refrigeration" button when the machine is turned on, and it will start with a one-minute delay. This is a normal phenomenon and the unit will enter the "refrigeration" operation state after one minute;
Cleaning of the bottom basin of industrial air conditioners: The controller is equipped with a "clean" button, which is used to clean the bottom basin and change water. The bottom basin must be cleaned once a day to ensure that the air sent out is fresh and clean; the cold medium of energy-saving and environmentally friendly air conditioners It is water, so the water source should be kept open for a long time, and a water pressure greater than 1.5Kg per square centimeter is required. When the unit is running, if there is no cooling effect, check whether there is a water shortage. If there is a shortage of water, the indicator light is on, and further check whether the faucet is closed, whether the water pressure is insufficient, whether the water inlet valve, water pump and water level sensor are damaged, etc.; when the temperature is low (Winter) or when the humidity is high (spring, rainy weather), you can press the "Air Supply" button to directly send fresh air into the room; stop by pressing the "Stop" button.
Jiangsu Jincheng Air Conditioning Engineering Co., Ltd. has been focusing on the design, development and production of industrial air conditioning equipment for many years. Its industrial refrigeration has a wide range of applications. Its main products are: industrial air conditioning, chemical fiber industrial air conditioning, textile industrial air conditioning, chemical fiber industrial refrigeration, and dust-free workshop refrigeration , Ventilation ducts, cooling towers, refrigerators and other air conditioning units and accessories.
Jiangsu Jincheng is a rare conscience manufacturer in the industrial refrigeration industry. If you want to know more product information, please contact: Mr. Song 13705113637 Website: http://xjdgzfs.cn/